CM2015 Periodic Verification Tool

  • The CM2015PV is a Periodic Verification Tool for the Resistance Ranger Constant Monitors
  • Quickly Verify That Constant Monitors are Calibrated and Operating according to Specifications
  • Resistor Box Containing 5% Fixed Precision Resistors That Simulate Pass / Fail conditions of ESD grounding Products
  • The CM1600, CM1601, CM1602, CM2815, CM2800 ESD constant monitors are factory calibrated and it is recommended to verify calibration annually with the CM2015PV periodic verification
SKU: CM2015PV
Price: $902.06

Available on backorder


CM2015 Periodic Verification Tool quickly and accurately verifies the calibration of the Ranger Series dual wire resistance constant monitors.

The CM2015PV is a resistance box with fixed 5% precision resistors. Resistance decade boxes can quickly and accurately simulate resistance for testing the accuracy of ESD testers and meters.

The CM2015PV works with the following monitors:

  • CM1600 – RangerPRO
  • CM1601 – RangerONE
  • CM1602 – RangerTWO
  • CM2815 – RangerNET
  • CM2800 – RangerBOSS

What is Resistance?
Resistance is the opposition to the passage of an electric current through an electrical conductor. Measured in ohms, and defined by Ohm’s Law as equal to voltage divided by current, resistance is one of the most basic of electrical measurements.

Calibration
The CM1600, CM1601, CM1602, CM2815, CM2800 ESD constant monitors are factory calibrated and it is recommended to verify calibration with the CM2015PV periodic verification. The following procedure will verify wrist strap and work surfaces. Please note that some models of the Ranger Series Constant Monitors has adjustable alarm limits. The procedure is for the default settings. Not all models monitor work surfaces, and you may skip that procedure.

Wrist Strap Verification Procedure

  1. Plug the CM2015PV’s main lead (Male Phono Plug) to the OP1 remote of the workstation monitor.
  2. To verify that the constant monitor’s resistance limits, turn the dial of the CM2015PV to each designated resistance in Table 1 below and record the constant monitor reaction. If the resistance of the wrist strap is less than 1.8M Safe, the “OP” led will be yellow and alarm will sound. For normal operating resistance of 1.8M Safe through 35M Safe, the “OP” led will be green. If the wrist strap resistance is higher than 35M High, “OP” led will be red and audible alarm will sound.
  3. Repeat procedure with PVU plugged into OP2 (if applicable).

Work Station Verification Procedure

  1. Plug the two test leads in the green inputs on the top of the CM2015PV and attach the alligator clips to the ends of the test leads.
  2. Detach the Mat Ground Cord from the mat, and clip the alligator clip to the stud on the underside of the head of the cable.
  3. Attach the other test lead to the snap on the mat.
  4. To verify that the mats resistance limits, turn the dial of the CM2015PV to each designated resistance in Table 2 and record the constant monitor reaction. For normal operating resistance of 0Ω – 100M Safe, the MAT led will be green. If MAT resistance is higher than 100M High, the Mat led will be red and audible alarm will sound.
  5. Repeat procedure with the 2nd work surface if connected.

If the monitor did not pass as per the test procedure call Transforming Technologies at (419) 841-9552 .