CM1602-resistance-ranger-dual-wire-constant-monitor

RangerTWO Dual Wire Constant Monitor – Model CM1602

Item #: CM1602

  • Monitors one dual wire wrist strap and one worksurface
  • Uses resistance based monitoring technology
  • Easy to use and economical
  • Audible and visual alarm indicators
Quantity:

Product Description

Dependable and accurate dual wire monitor for one person and one work surface.

The Resistance Ranger Series is the most reliable workstation monitoring system available. The extremely sensitive monitors accurately measure the electrical resistance of an ESD wrist band and work surface and signals if the devices fail.

The RangerTWO is an extremely sensitive and reliable ground monitoring instrument. Audible and visible alarms are triggered if the operator’s resistance exceeds 35 megohm. Low resistance of 1.8 megohm also triggers an alarm event. Mat alarm limits are set at 100 meg ohm.

Accessories

CyclopsTM Operator Presence Check
The Cyclops is an infrared sensor that causes the monitor to alarm when an operator approaches the workstation without connecting their wrist strap. The alarm continues until compliance is achieved.  Part number:  CMREMOTE-IR

 Wrist Strap Parking Station
Provides a jack that will allow an operator to disconnect and leave the dual conductor cord at the workstation without the wrist strap monitoring system alarm sounding. For use with mono plug coil cords. Part number: CP3000

Operator Presence Check

The RangerTWO can be outfitted with the Cyclops Remote Sensor that detects the presence of an operator and alarms if a wrist strap is not connected to prevent ungrounded handling of ESD susceptible items

Calibration

The  RangerTWO is factory calibrated and does not require annual re-calibration.  It is recommended to verify calibration with the CM2015PV periodic verification meter at least once a year.  Download the RangerTWO calibration statement for your compliance program.

Superior Technology
Resistance based monitoring is the only true wrist strap monitoring technology available. Single wire systems simply detect that a person is wearing a wrist strap and put the monitor into an unalarmed state. Resistance monitors actually measure the resistance of the wrist strap in combination with the person and alarm if the product exceeds preset levels. This accurate measurement ensures reliability.

Additional Information

Weight 0.5 lbs
Dimensions 4 x 1 x 3 in
Type

Dual Wire Resistance Monitoring

Capabilties

Monitors 1 Wriststrap and 1 Worksurface

Sensing Current

max 0.1V (100mV)

Power

100-240 VAC, 1A.

Wrist Strap Alarm Limit

Low Resistance: 1.8 megohm
High Resistance: 35 meg ohm

Mat Alarm Limit

100 meg ohm

You may also like…

RangerONE Dual Wire Constant Monitor – Model CM1601

CM1601-resistance-ranger-dual-wire-constant-monitor

Dependable and accurate dual wire monitor for one person.

The RangerOne is an extremely sensitive monitor that accurately measures the electrical resistance of an ESD wrist band and signals if the device fail. The Resistance Ranger Series is the most reliable workstation monitoring system available.

The extremely sensitive monitors accurately measure the electrical resistance of an ESD wrist band and work surface and signals if the devices fail. Audible and visible alarms are triggered if the operator’s resistance exceeds 35 meg ohm. The Ranger Series saves time by eliminating the time-consuming testing of wrist straps and coil cords.

Accessories

CyclopsTM Operator Presence Check
The Cyclops is an infrared sensor that causes the monitor to alarm when an operator approaches the workstation without connecting their wrist strap. The alarm continues until compliance is achieved.  Part number:  CMREMOTE-IR

 Wrist Strap Parking Station
Provides a jack that will allow an operator to disconnect and leave the dual conductor cord at the workstation without the wrist strap monitoring system alarm sounding. For use with mono plug coil cords. Part number: CP3000

Operator Presence Check

The RangerONE can be outfitted with the Cyclops Remote Sensor that detects the presence of an operator and alarms if a wrist strap is not connected to prevent ungrounded handling of ESD susceptible items

Calibration

The  RangerONE is factory calibrated and does not require annual re-calibration.  It is recommended to verify calibration with the CM2015PV periodic verification meter at least once a year.  Download the RangerONEcalibration statement for your compliance program.

Superior Technology
Resistance based monitoring is the only true wrist strap monitoring technology available. Single wire systems simply detect that a person is wearing a wrist strap and put the monitor into an unalarmed state. Resistance monitors actually measure the resistance of the wrist strap in combination with the person and alarm if the product exceeds preset levels. This accurate measurement ensures reliability.

More Info Add to cart

Add to quote

RangerPRO Dual Wire Constant Monitor – CM1600

cm1600-dual-conductor-constant-monitor

Versatile, Dependable, and Accurate Resistance Based Constant Monitor System

The RangerPRO constant monitor is the premiere work station grounding system available. A continuous pulse of an ultra-low voltage signal measures the electrical resistance of two wrist bands, two work surfaces, and two auxiliary grounds simultaneously and alarms if there is a problem.

The RangerPRO is an extremely sensitive and reliable ground monitoring instrument. Audible and visible alarms are triggered if the operator’s resistance exceeds 35 megohm . Low resistance can also triggers an alarm event. Mat alarm limits are set at 100 meg ohm. The CM1600 packaged in a stainless steel case with two wrist strap jacks.

The RangerPRO saves time by eliminating the time-consuming testing of grounding products. The system uses special dual wire wrist band sets that contain two independent elements which provide fail-safe protection. The series includes both fabric and metal wrist bands paired with cords in either 5, 10, or 20 feet lengths.
Meets or exceeds requirements of ANSI ESD-S20.20 and ESDA Standard 1.1-2006

Operator Presence Check

The RangerPRO can be outfitted with the Cyclops Remote Sensor that detects the presence of an operator and alarms if a wrist strap is not connected to prevent ungrounded handling of ESD susceptible items.

Alarm Signals

The RangerPRO works with light towers, sirens, and other devices to enhance the signal of a failure. Pair the unit with the CM-RELAY to integrate with a signal (check with the manufacturer of your signal for compatibility.)

Calibration

The RangerPRO is factory calibrated and does not require annual re-calibration.  It is recommended to verify calibration with the CM2015PV periodic verification meter at least once a year.  Download the RangerTWO calibration statement for your compliance program.

More Info Add to cart

Add to quote